Page 3-151
... combustible insulation when the heat content of the facing and substrate of the insulation material does not exceed ... combustible sur- faces , one sprinkler shall be installed at each alternate floor level . Where a shaft having ...
... combustible insulation when the heat content of the facing and substrate of the insulation material does not exceed ... combustible sur- faces , one sprinkler shall be installed at each alternate floor level . Where a shaft having ...
Page 3-152
... combustible roofs or canopies exceeding 4 ft ( 1.2 m ) in width . 4-4.1.7.7 Dwelling Units . 4-4.1.7.7.1 Sprinklers are not required in bathrooms that are located within dwelling units , that do not exceed 55 sq ft ( 5.1 m2 ) , and that ...
... combustible roofs or canopies exceeding 4 ft ( 1.2 m ) in width . 4-4.1.7.7 Dwelling Units . 4-4.1.7.7.1 Sprinklers are not required in bathrooms that are located within dwelling units , that do not exceed 55 sq ft ( 5.1 m2 ) , and that ...
Page 3-507
... COMBUSTIBLE COMPONENTS USING THE INTERMEDIATE - SCALE , MULTISTORY TEST APPARATUS Test Standard of the International Conference of Building Officials See Section 2602.5.2.2 , Uniform Building Code NOTE : This is a new standard . 687 ...
... COMBUSTIBLE COMPONENTS USING THE INTERMEDIATE - SCALE , MULTISTORY TEST APPARATUS Test Standard of the International Conference of Building Officials See Section 2602.5.2.2 , Uniform Building Code NOTE : This is a new standard . 687 ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 3-1 |
System Acceptance 13 65 | 3-13 |
Means of Egress | 3-17 |
Copyright | |
18 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied assembly ASTM authority having jurisdiction beams Brace branch lines brick building official calculated ceiling check valve classification combustible concrete masonry concrete masonry units construction control valve curtain deck determined device diameter dimensions door dry pipe valve edge edition NFPA equipment exceed Exception face feet Figure fire department connection fire test fire-endurance fire-resistance rating Flanges floor flow grade gypsum hangers heat horizontal hose connections hose stations hose stream hydraulically hydrostatic test installed joints joist length less liquid limit listed load located material maximum minimum mortar opening operation panels percent permitted pipe system plasticity index plywood pressure prism protection requirements riser roof Screw SECTION shakes side spaced specified sprinkler system sq ft standpipe system storage surface Table temperature test sample test specimen thermocouples tion tube Type UBC Standard Uniform Building Code veneer vertical water supply weight welding width wire wood