Page 3-25
... face width of the top horizontal board of a core having the top edge inclined shall not be less than 3 inches ( 76.2 mm ) . See Figures 7-3-3 , 7-3-4 and 7-3-5 . SECTION 7.308 — NAILING OF CORES - 7.308.1 General . The boards shall be ...
... face width of the top horizontal board of a core having the top edge inclined shall not be less than 3 inches ( 76.2 mm ) . See Figures 7-3-3 , 7-3-4 and 7-3-5 . SECTION 7.308 — NAILING OF CORES - 7.308.1 General . The boards shall be ...
Page 3-26
... faces of the core shall be covered with sections laid with their longer sides vertical , except that the sections in one ver- tical row on each face of the core may be laid horizontally . Vertical seams formed with face sections shall ...
... faces of the core shall be covered with sections laid with their longer sides vertical , except that the sections in one ver- tical row on each face of the core may be laid horizontally . Vertical seams formed with face sections shall ...
Page 3-314
... face are not permitted . 15.315.2.5 Stain . Medium blue stain is permitted . 15.315.2.6 Unsound wood . Unsound wood is prohibited on ei- ther face . 15.315.2.7 Warp . Facial curvature ( bow ) , twist , or both , shall not exceed 1/4 ...
... face are not permitted . 15.315.2.5 Stain . Medium blue stain is permitted . 15.315.2.6 Unsound wood . Unsound wood is prohibited on ei- ther face . 15.315.2.7 Warp . Facial curvature ( bow ) , twist , or both , shall not exceed 1/4 ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 3-1 |
System Acceptance 13 65 | 3-13 |
Means of Egress | 3-17 |
Copyright | |
18 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied assembly ASTM authority having jurisdiction beams Brace branch lines brick building official calculated ceiling check valve classification combustible concrete masonry concrete masonry units construction control valve curtain deck determined device diameter dimensions door dry pipe valve edge edition NFPA equipment exceed Exception face feet Figure fire department connection fire test fire-endurance fire-resistance rating Flanges floor flow grade gypsum hangers heat horizontal hose connections hose stations hose stream hydraulically hydrostatic test installed joints joist length less liquid limit listed load located material maximum minimum mortar opening operation panels percent permitted pipe system plasticity index plywood pressure prism protection requirements riser roof Screw SECTION shakes side spaced specified sprinkler system sq ft standpipe system storage surface Table temperature test sample test specimen thermocouples tion tube Type UBC Standard Uniform Building Code veneer vertical water supply weight welding width wire wood