Uniform Building Code: 1952, Volume 3International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 86
Page 3-128
... listed in accordance with 2-3.5 shall be in accordance with the listing requirements . 2-3.4 * Copper tube as specified in the standards listed in Table 2-3.1 shall have a wall thickness of Type K , L , or M where used in sprinkler ...
... listed in accordance with 2-3.5 shall be in accordance with the listing requirements . 2-3.4 * Copper tube as specified in the standards listed in Table 2-3.1 shall have a wall thickness of Type K , L , or M where used in sprinkler ...
Page 3-130
... listed for this service shall be permitted when installed in accor- dance with their listing limitations , including installation instructions . 2-5.6 End Treatment . After cutting , pipe ends shall have burrs and fins removed . 2-5.6.1 ...
... listed for this service shall be permitted when installed in accor- dance with their listing limitations , including installation instructions . 2-5.6 End Treatment . After cutting , pipe ends shall have burrs and fins removed . 2-5.6.1 ...
Page 3-250
... listed indicating valves . Such valves shall not close in less than 5 sec when operated at maximum possible speed from the fully open position . Exception No. 1 : A listed underground gate valve equipped with a listed indicator post ...
... listed indicating valves . Such valves shall not close in less than 5 sec when operated at maximum possible speed from the fully open position . Exception No. 1 : A listed underground gate valve equipped with a listed indicator post ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 3-1 |
System Acceptance 13 65 | 3-13 |
Means of Egress | 3-17 |
Copyright | |
18 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied assembly ASTM authority having jurisdiction beams Brace branch lines brick building official calculated ceiling check valve classification combustible concrete masonry concrete masonry units construction control valve curtain deck determined device diameter dimensions door dry pipe valve edge edition NFPA equipment exceed Exception face feet Figure fire department connection fire test fire-endurance fire-resistance rating Flanges floor flow grade gypsum hangers heat horizontal hose connections hose stations hose stream hydraulically hydrostatic test installed joints joist length less liquid limit listed load located material maximum minimum mortar opening operation panels percent permitted pipe system plasticity index plywood pressure prism protection requirements riser roof Screw SECTION shakes side spaced specified sprinkler system sq ft standpipe system storage surface Table temperature test sample test specimen thermocouples tion tube Type UBC Standard Uniform Building Code veneer vertical water supply weight welding width wire wood