Uniform Building Code: 1952, Volume 3International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 76
Page 3-12
... LOADING Throughout the fire - endurance and fire and hose stream tests , apply a constant superimposed load to simulate a maximum load condition . The applied load shall be as nearly as practicable the maximum load allowed by design ...
... LOADING Throughout the fire - endurance and fire and hose stream tests , apply a constant superimposed load to simulate a maximum load condition . The applied load shall be as nearly as practicable the maximum load allowed by design ...
Page 3-87
... LOAD ON MEMBER AS PERCENT OF ALLOWABLE FIGURE 7-7-1 - LOAD FACTOR For columns having a Keds 11 , Z shall be determined as follows : Where the ratio of applied load to allowable load is equal to or less than 50 , Z = 1.5 . Where the ...
... LOAD ON MEMBER AS PERCENT OF ALLOWABLE FIGURE 7-7-1 - LOAD FACTOR For columns having a Keds 11 , Z shall be determined as follows : Where the ratio of applied load to allowable load is equal to or less than 50 , Z = 1.5 . Where the ...
Page 3-293
... load of four times the design load when installed in the manner intended for use . Test loads shall be applied for a period of one hour . 10.304.2 Exit ladder devices of the retractable type shall , in addi- tion to the static load ...
... load of four times the design load when installed in the manner intended for use . Test loads shall be applied for a period of one hour . 10.304.2 Exit ladder devices of the retractable type shall , in addi- tion to the static load ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 3-1 |
System Acceptance 13 65 | 3-13 |
Means of Egress | 3-17 |
Copyright | |
18 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied assembly ASTM authority having jurisdiction beams Brace branch lines brick building official calculated ceiling check valve classification combustible concrete masonry concrete masonry units construction control valve curtain deck determined device diameter dimensions door dry pipe valve edge edition NFPA equipment exceed Exception face feet Figure fire department connection fire test fire-endurance fire-resistance rating Flanges floor flow grade gypsum hangers heat horizontal hose connections hose stations hose stream hydraulically hydrostatic test installed joints joist length less liquid limit listed load located material maximum minimum mortar opening operation panels percent permitted pipe system plasticity index plywood pressure prism protection requirements riser roof Screw SECTION shakes side spaced specified sprinkler system sq ft standpipe system storage surface Table temperature test sample test specimen thermocouples tion tube Type UBC Standard Uniform Building Code veneer vertical water supply weight welding width wire wood