Uniform Building Code: 1952, Volume 3International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 89
Page 3-3
... opening . ( See Figure 4-1-1 . ) FRAME PROSCENIUM FIRESAFETY CURTAIN is a curtain that has a rigid frame , and stores over the proscenium opening in one flat panel . MODIFIED FRAME PROSCENIUM FIRESAFETY CURTAIN is a curtain made of ...
... opening . ( See Figure 4-1-1 . ) FRAME PROSCENIUM FIRESAFETY CURTAIN is a curtain that has a rigid frame , and stores over the proscenium opening in one flat panel . MODIFIED FRAME PROSCENIUM FIRESAFETY CURTAIN is a curtain made of ...
Page 3-289
... Opening Degree . When manually operated in the di- rection of egress , leaves of swinging doors or swing - out ... opening and closing forces , and the speed of opening and closing , shall be recorded at the start of the endurance tests ...
... Opening Degree . When manually operated in the di- rection of egress , leaves of swinging doors or swing - out ... opening and closing forces , and the speed of opening and closing , shall be recorded at the start of the endurance tests ...
Page 3-290
... opening with the center line of the carpet in the center line of the door opening . The width shall be measured be- tween the exposed edges of the carpet tread surface excluding molded edge bevels or edge trim . 2. The length of ...
... opening with the center line of the carpet in the center line of the door opening . The width shall be measured be- tween the exposed edges of the carpet tread surface excluding molded edge bevels or edge trim . 2. The length of ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 3-1 |
System Acceptance 13 65 | 3-13 |
Means of Egress | 3-17 |
Copyright | |
18 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied assembly ASTM authority having jurisdiction beams Brace branch lines brick building official calculated ceiling check valve classification combustible concrete masonry concrete masonry units construction control valve curtain deck determined device diameter dimensions door dry pipe valve edge edition NFPA equipment exceed Exception face feet Figure fire department connection fire test fire-endurance fire-resistance rating Flanges floor flow grade gypsum hangers heat horizontal hose connections hose stations hose stream hydraulically hydrostatic test installed joints joist length less liquid limit listed load located material maximum minimum mortar opening operation panels percent permitted pipe system plasticity index plywood pressure prism protection requirements riser roof Screw SECTION shakes side spaced specified sprinkler system sq ft standpipe system storage surface Table temperature test sample test specimen thermocouples tion tube Type UBC Standard Uniform Building Code veneer vertical water supply weight welding width wire wood