Uniform Building Code: 1952, Volume 3International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 78
Page 3-327
... percent of the test sample is retained on the No. 200 ( 75 μm ) sieve . 3. Classify the soil as fine - grained if 50 percent or more of the test sample passes the No. 200 ( 75 μm ) sieve . SECTION 18.106- PROCEDURE FOR CLASSIFICATION OF ...
... percent of the test sample is retained on the No. 200 ( 75 μm ) sieve . 3. Classify the soil as fine - grained if 50 percent or more of the test sample passes the No. 200 ( 75 μm ) sieve . SECTION 18.106- PROCEDURE FOR CLASSIFICATION OF ...
Page 3-348
... percent of a shipment may have slight cracks or small chips not larger than 1 inch ( 25.4 mm ) . SECTION 21.408 ... PERCENT OF TOTAL ABSORPTION LINEAR SHRINKAGE , PERCENT 0.03 or less From 0.03 to 0.045 0.045 to 0.065 , max . 1 Average ...
... percent of a shipment may have slight cracks or small chips not larger than 1 inch ( 25.4 mm ) . SECTION 21.408 ... PERCENT OF TOTAL ABSORPTION LINEAR SHRINKAGE , PERCENT 0.03 or less From 0.03 to 0.045 0.045 to 0.065 , max . 1 Average ...
Page 3-406
... percent grade and dimensional tolerance , a 5 percent tol- erance shall apply separately to the inner - ply gap limitations , in- cluding the limitations applicable to the plugged crossband and jointed crossband , as specified in ...
... percent grade and dimensional tolerance , a 5 percent tol- erance shall apply separately to the inner - ply gap limitations , in- cluding the limitations applicable to the plugged crossband and jointed crossband , as specified in ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 3-1 |
System Acceptance 13 65 | 3-13 |
Means of Egress | 3-17 |
Copyright | |
18 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied assembly ASTM authority having jurisdiction beams Brace branch lines brick building official calculated ceiling check valve classification combustible concrete masonry concrete masonry units construction control valve curtain deck determined device diameter dimensions door dry pipe valve edge edition NFPA equipment exceed Exception face feet Figure fire department connection fire test fire-endurance fire-resistance rating Flanges floor flow grade gypsum hangers heat horizontal hose connections hose stations hose stream hydraulically hydrostatic test installed joints joist length less liquid limit listed load located material maximum minimum mortar opening operation panels percent permitted pipe system plasticity index plywood pressure prism protection requirements riser roof Screw SECTION shakes side spaced specified sprinkler system sq ft standpipe system storage surface Table temperature test sample test specimen thermocouples tion tube Type UBC Standard Uniform Building Code veneer vertical water supply weight welding width wire wood