Uniform Building Code: 1952, Volume 3International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 95
Page 3-128
... Pipe and Tube . 2-3.1 Pipe or tube used in sprinkler systems shall meet or exceed one of the standards in Table 2-3.1 or be in accor- dance with 2-3.2 through 2-3.5 . Table 2-3.1 Pipe or Tube Materials and Dimensions Materials and ...
... Pipe and Tube . 2-3.1 Pipe or tube used in sprinkler systems shall meet or exceed one of the standards in Table 2-3.1 or be in accor- dance with 2-3.2 through 2-3.5 . Table 2-3.1 Pipe or Tube Materials and Dimensions Materials and ...
Page 3-195
... piping take into consideration the weight of water - filled pipe plus a safety factor . No allowance has been made for the hanging of nonsystem components from sprinkler piping . A - 2-6.3.1 Powder - driven studs should not be used in ...
... piping take into consideration the weight of water - filled pipe plus a safety factor . No allowance has been made for the hanging of nonsystem components from sprinkler piping . A - 2-6.3.1 Powder - driven studs should not be used in ...
Page 3-245
... Piping Ductile - Iron Pipe , Centrifugally Cast , in Metal Molds or Sand - Lined Molds for Water or Other Liquids AWWA C151 2-2.6 Pipe Bending . Bending of Schedule 40 steel pipe and Types K and L copper tube shall be permitted where ...
... Piping Ductile - Iron Pipe , Centrifugally Cast , in Metal Molds or Sand - Lined Molds for Water or Other Liquids AWWA C151 2-2.6 Pipe Bending . Bending of Schedule 40 steel pipe and Types K and L copper tube shall be permitted where ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 3-1 |
System Acceptance 13 65 | 3-13 |
Means of Egress | 3-17 |
Copyright | |
18 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied assembly ASTM authority having jurisdiction beams Brace branch lines brick building official calculated ceiling check valve classification combustible concrete masonry concrete masonry units construction control valve curtain deck determined device diameter dimensions door dry pipe valve edge edition NFPA equipment exceed Exception face feet Figure fire department connection fire test fire-endurance fire-resistance rating Flanges floor flow grade gypsum hangers heat horizontal hose connections hose stations hose stream hydraulically hydrostatic test installed joints joist length less liquid limit listed load located material maximum minimum mortar opening operation panels percent permitted pipe system plasticity index plywood pressure prism protection requirements riser roof Screw SECTION shakes side spaced specified sprinkler system sq ft standpipe system storage surface Table temperature test sample test specimen thermocouples tion tube Type UBC Standard Uniform Building Code veneer vertical water supply weight welding width wire wood