Uniform Building Code: 1952, Volume 3International Conference of Building Officials, 1997 - Building laws |
From inside the book
Results 1-3 of 82
Page 3-40
... SAMPLE The construction of the test sample shall be of sufficient size and include all conduits , pipes , cables ( jacket types , sizes , conductor types , percent fills ) , required supports or other penetrating items so as to produce ...
... SAMPLE The construction of the test sample shall be of sufficient size and include all conduits , pipes , cables ( jacket types , sizes , conductor types , percent fills ) , required supports or other penetrating items so as to produce ...
Page 3-321
... sample . The loading knife edge may be either the fixed or the rocker type and shall be at least as long as the width of the sample . Place the sample on the knife edges with the open side or turned- down edges down , so that the sample ...
... sample . The loading knife edge may be either the fixed or the rocker type and shall be at least as long as the width of the sample . Place the sample on the knife edges with the open side or turned- down edges down , so that the sample ...
Page 3-327
... sampling by auger borings , for Pene- tration Test and Split - barrel Sampling of Soils , and for Thin - walled Tube Sampling of Soils . The sample shall be carefully identified as to origin by a boring number and sample number in ...
... sampling by auger borings , for Pene- tration Test and Split - barrel Sampling of Soils , and for Thin - walled Tube Sampling of Soils . The sample shall be carefully identified as to origin by a boring number and sample number in ...
Contents
UBC Standard 21 Noncombustible MaterialTests | 3-1 |
System Acceptance 13 65 | 3-13 |
Means of Egress | 3-17 |
Copyright | |
18 other sections not shown
Other editions - View all
Common terms and phrases
accordance ANSI applied assembly ASTM authority having jurisdiction beams Brace branch lines brick building official calculated ceiling check valve classification combustible concrete masonry concrete masonry units construction control valve curtain deck determined device diameter dimensions door dry pipe valve edge edition NFPA equipment exceed Exception face feet Figure fire department connection fire test fire-endurance fire-resistance rating Flanges floor flow grade gypsum hangers heat horizontal hose connections hose stations hose stream hydraulically hydrostatic test installed joints joist length less liquid limit listed load located material maximum minimum mortar opening operation panels percent permitted pipe system plasticity index plywood pressure prism protection requirements riser roof Screw SECTION shakes side spaced specified sprinkler system sq ft standpipe system storage surface Table temperature test sample test specimen thermocouples tion tube Type UBC Standard Uniform Building Code veneer vertical water supply weight welding width wire wood