Proceedings of the ... International Conference on Offshore Mechanics and Arctic Engineering, Volume 3American Society of Mechanical Engineers, 2002 - Arctic regions |
From inside the book
Results 1-3 of 78
Page 3
... ranges the fatigue limit is reached in air preventing comparison , but there is approximately a factor 8 or more including one run - out , between the two carbon dioxide containing environments at 550 MPa stress range . The observation ...
... ranges the fatigue limit is reached in air preventing comparison , but there is approximately a factor 8 or more including one run - out , between the two carbon dioxide containing environments at 550 MPa stress range . The observation ...
Page 56
... range found in the measurements and the calculated value ( whatever position along the pipe the maximum stress range occurred ) as a function of the applied angle range for pipe angular position 0 ° . Figure 8 shows the corresponding ...
... range found in the measurements and the calculated value ( whatever position along the pipe the maximum stress range occurred ) as a function of the applied angle range for pipe angular position 0 ° . Figure 8 shows the corresponding ...
Page 563
... range with a local stress intensity maximum may be more appropriate damage indicator . Bouyssy et al [ 38 ] stated that for broad band processes , rainflow ranges lead to an upper band for the accumulated damage while local ranges lead ...
... range with a local stress intensity maximum may be more appropriate damage indicator . Bouyssy et al [ 38 ] stated that for broad band processes , rainflow ranges lead to an upper band for the accumulated damage while local ranges lead ...
Other editions - View all
Common terms and phrases
alloys analysis applied approximately assessment bending calculated carried coating compared composite compressive considered corrosion crack crack growth curve cycles damage defect deformation depth determined developed direction distribution effect element Engineering equation estimated evaluation experience factor failure fatigue field Figure flaw flexible fracture function geometry given Grade heat higher hydrogen important increase initial installation insulation integrity International joint length limit load locations lower material maximum mean measured mechanical method observed obtained Offshore operation parameters performed pipe plate predicted present pressure problem procedure production properties range reliability residual resistance respectively riser rope safety samples shown shows side simulation solution specimens standard steel strain strength stress structure surface Table temperature tensile tension thermal thickness titanium toughness uncertainties variables weld