Proceedings of the ... International Conference on Offshore Mechanics and Arctic Engineering, Volume 3American Society of Mechanical Engineers, 2002 - Arctic regions |
From inside the book
Results 1-3 of 85
Page 8
... samples were fitted into the pressure cell as shown in Fig . 2 . The samples were slightly oversized so that it was a tight seal between the cell and the sample . The whole cell with the sample was placed in a hot cabinet . Fig . 2 also ...
... samples were fitted into the pressure cell as shown in Fig . 2 . The samples were slightly oversized so that it was a tight seal between the cell and the sample . The whole cell with the sample was placed in a hot cabinet . Fig . 2 also ...
Page 212
... samples were cleaned ultrasonically in ethylic alcohol . To remove the excess moisture , the samples were held for a certain time in a sample - drying oven at 70 ° C . The PE , PA and PU were dried for 24 hours and the rubbers for 72 ...
... samples were cleaned ultrasonically in ethylic alcohol . To remove the excess moisture , the samples were held for a certain time in a sample - drying oven at 70 ° C . The PE , PA and PU were dried for 24 hours and the rubbers for 72 ...
Page 495
... samples . The samples were degreased in isopropanol and cleaned in distilled water . The hydrogen concentration was determined in approximately 100mg samples . The main part of these was cut from the top of the C - ring specimens and ...
... samples . The samples were degreased in isopropanol and cleaned in distilled water . The hydrogen concentration was determined in approximately 100mg samples . The main part of these was cut from the top of the C - ring specimens and ...
Other editions - View all
Common terms and phrases
alloys analysis applied approximately assessment bending calculated carried coating compared composite compressive considered corrosion crack crack growth curve cycles damage defect deformation depth determined developed direction distribution effect element Engineering equation estimated evaluation experience factor failure fatigue field Figure flaw flexible fracture function geometry given Grade heat higher hydrogen important increase initial installation insulation integrity International joint length limit load locations lower material maximum mean measured mechanical method observed obtained Offshore operation parameters performed pipe plate predicted present pressure problem procedure production properties range reliability residual resistance respectively riser rope safety samples shown shows side simulation solution specimens standard steel strain strength stress structure surface Table temperature tensile tension thermal thickness titanium toughness uncertainties variables weld