Physical Principles and Techniques of Protein Chemistry, Part 2Sydney J. Leach, Sidney J. Leach Physical Principles and Techniques of Protein Chemistry, Part B deals with the theories and application of selected physical methods in protein chemistry evaluation. This book is divided into seven chapters that cover the ultracentrifugal analysis, light scattering, infrared (IR) methods, nuclear magnetic resonance (NMR) spectroscopy, and differential thermal analysis of protein properties. This text first describes the fundamental ideas and methodology of sedimentation analysis of ideal noninteracting solutes and the problems of nonideality and solute-solute interaction. This book then deals ... |
From inside the book
Results 1-3 of 78
Page 133
... ( obtained from D ° or s ° ) in Eq . ( 56 ) allows the calculation of M. This method can give quite reasonable results ... obtained , which , like ß , is rather insensitive to axial ratio . A reasonable value of the latter is chosen , B ...
... ( obtained from D ° or s ° ) in Eq . ( 56 ) allows the calculation of M. This method can give quite reasonable results ... obtained , which , like ß , is rather insensitive to axial ratio . A reasonable value of the latter is chosen , B ...
Page 169
... obtained from sedi- mentation equilibrium and small - angle X - ray scattering data if the partial specific volume and electron density increment , respectively , are obtained using a dialyzed solution and the dialyzate as solution and ...
... obtained from sedi- mentation equilibrium and small - angle X - ray scattering data if the partial specific volume and electron density increment , respectively , are obtained using a dialyzed solution and the dialyzate as solution and ...
Page 303
... obtained in this way are sensitive to any distortion . of the resonance signal and also to the intensity of the rf field used . Instrumental limits allow T1 values to be measured in the range of 0.3- 10 sec . Values of T1 may also be ...
... obtained in this way are sensitive to any distortion . of the resonance signal and also to the intensity of the rf field used . Instrumental limits allow T1 values to be measured in the range of 0.3- 10 sec . Values of T1 may also be ...
Contents
Ultracentrifugal Analysis | 1 |
J H Coates Glossary of Symbols 23435 37 | 2 |
Fundamentals of the Method | 5 |
Copyright | |
51 other sections not shown
Other editions - View all
Common terms and phrases
absorption acid amino anions atoms axial ratio band beam binding Biol bond Bradbury calculated capillary cell centrifugal chain changes Chem chemical shifts complex component concentration constant copper(II denaturation density gradient dependence determined dilution Doty effect electron ellipsoid enzyme equation extrapolation field Fraser frequency fringe Gurd histidine hydrogen ion imidazole imidazole groups instrument interaction intrinsic viscosity Jardetzky length light scattering light-scattering line width lysozyme macromolecule magnetic measured meniscus metal ion method molecular weight molecule myoglobin nuclei observed obtained optical density optical system partial specific volume particle PBLG peak peptide Phys plot Polymer Sci Proc protein solution protons random coil Rayleigh reference refractive index region relaxation residues resonance RNase rotation rotor sample schlieren Section sedimentation coefficient shearing stress slit solvent spectra spectrum speed structure studies Tanford technique temperature Timasheff tion transition ultracentrifuge values velocity Vinograd viscometer zero zone