Page 9
... Exceptions and Deviations SEC . 1101 . Mixed Occupancies Requirements for Group F Occupancies 62 Group F Occupancies Defined 1102. Construction , Height and Area 1103 . 1104 . 1106 . Allowable Location on Property Exit Facilities 1105 ...
... Exceptions and Deviations SEC . 1101 . Mixed Occupancies Requirements for Group F Occupancies 62 Group F Occupancies Defined 1102. Construction , Height and Area 1103 . 1104 . 1106 . Allowable Location on Property Exit Facilities 1105 ...
Page 47
... exceptions : 1. A foyer shall not be required . 2. No balcony or gallery shall be allowed except in build- ings of Type I construction . Exception : This shall not apply to balconies in a school gymnasium , provided that there is no ...
... exceptions : 1. A foyer shall not be required . 2. No balcony or gallery shall be allowed except in build- ings of Type I construction . Exception : This shall not apply to balconies in a school gymnasium , provided that there is no ...
Page 51
... exceptions : 1. A foyer shall not be required . 2. Seats shall not be required to be fixed . 3. Divisions 2 and 3 when ... Exception : This shall not apply to balconies in a school gymnasium , provided that there is no stage in the gym ...
... exceptions : 1. A foyer shall not be required . 2. Seats shall not be required to be fixed . 3. Divisions 2 and 3 when ... Exception : This shall not apply to balconies in a school gymnasium , provided that there is no stage in the gym ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood