Uniform Building CodePacific Coast Building Officials Conference, 1940 - Building laws |
From inside the book
Results 1-3 of 88
Page 72
... Fire Zone No. 1 PART IV REQUIREMENTS BASED ON LOCATION IN FIRE ZONES CHAPTER 16 - RESTRICTIONS IN FIRE ZONES Sec . 1601. ( a ) General . For the purpose of this Code , the entire city is hereby declared to be and is hereby established a ...
... Fire Zone No. 1 PART IV REQUIREMENTS BASED ON LOCATION IN FIRE ZONES CHAPTER 16 - RESTRICTIONS IN FIRE ZONES Sec . 1601. ( a ) General . For the purpose of this Code , the entire city is hereby declared to be and is hereby established a ...
Page 73
... fire - resistive construction as set forth in Section 4304 . For the purpose of this subsection , the center line of an ad- joining alley may be considered as the adjacent property ... Fire Zone No. 3 four - hour fire 73 Sections 1602-1603.
... fire - resistive construction as set forth in Section 4304 . For the purpose of this subsection , the center line of an ad- joining alley may be considered as the adjacent property ... Fire Zone No. 3 four - hour fire 73 Sections 1602-1603.
Page 259
... FIRE PROTECTION CHAPTER 42 - GENERAL Sec . 4201. Building materials , systems , units and forms of Fire - Re- construction as regulated by this Code shall be classified as sistive " four - hour fire - resistive construction , " " three ...
... FIRE PROTECTION CHAPTER 42 - GENERAL Sec . 4201. Building materials , systems , units and forms of Fire - Re- construction as regulated by this Code shall be classified as sistive " four - hour fire - resistive construction , " " three ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood