Uniform Building CodePacific Coast Building Officials Conference, 1940 - Building laws |
From inside the book
Results 1-3 of 41
Page 51
... adjacent property lines , shall be provided with doors and windows of one - hour fire - resistive construction as specified in Section 4304 . When any portion of a Division 4 occupancy is less than ten feet ( 10 ' ) from adjacent ...
... adjacent property lines , shall be provided with doors and windows of one - hour fire - resistive construction as specified in Section 4304 . When any portion of a Division 4 occupancy is less than ten feet ( 10 ' ) from adjacent ...
Page 59
... adjacent property lines , shall be provided with doors or windows of one - hour fire - resistive construction as specified in Section 4304. See Section 504 for regulating adjacent buildings on the same property . Sec . 1004. All Group E ...
... adjacent property lines , shall be provided with doors or windows of one - hour fire - resistive construction as specified in Section 4304. See Section 504 for regulating adjacent buildings on the same property . Sec . 1004. All Group E ...
Page 63
... adjacent property lines shall be provided with doors and windows of one - hour fire - resistive construction as specified in Section 4304. See Section 504 for regulating adjacent buildings on the same property . Sec . 1104. Stairs and ...
... adjacent property lines shall be provided with doors and windows of one - hour fire - resistive construction as specified in Section 4304. See Section 504 for regulating adjacent buildings on the same property . Sec . 1104. Stairs and ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood