Uniform Building CodePacific Coast Building Officials Conference, 1940 - Building laws |
From inside the book
Results 1-3 of 68
Page 22
... APPROVED . " One such approved set of plans and specifications shall be retained by the Building Inspector as a public record , for a period of not less than 90 days from date of completion of the work covered therein , and one set of ...
... APPROVED . " One such approved set of plans and specifications shall be retained by the Building Inspector as a public record , for a period of not less than 90 days from date of completion of the work covered therein , and one set of ...
Page 94
... Approved fiber board not less than seven - sixteenths inch ( 7/16 " ) thick . Approved gypsum sheathing not less than one - half inch ( 1⁄2 " ) thick . Approved plywood not less than five - sixteenths inch ( 5/16 ′′ ) thick . All Type V ...
... Approved fiber board not less than seven - sixteenths inch ( 7/16 " ) thick . Approved gypsum sheathing not less than one - half inch ( 1⁄2 " ) thick . Approved plywood not less than five - sixteenths inch ( 5/16 ′′ ) thick . All Type V ...
Page 311
... approved brand of interior stucco , which may be applied over a brown mortar surface that is still green . 2. A white coat consisting of one part gypsum plaster to not more than an equal amount of lime putty thoroughly gauged together ...
... approved brand of interior stucco , which may be applied over a brown mortar surface that is still green . 2. A white coat consisting of one part gypsum plaster to not more than an equal amount of lime putty thoroughly gauged together ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood