Uniform Building CodePacific Coast Building Officials Conference, 1940 - Building laws |
From inside the book
Results 1-3 of 9
Page 62
... automatic sprinkler system as provided in Chapter 38 , the permissible areas shown may be increased 100 per cent . 2. The area of a Group F occupancy of Types II and III construction may exceed that set forth in Table No. I of this ...
... automatic sprinkler system as provided in Chapter 38 , the permissible areas shown may be increased 100 per cent . 2. The area of a Group F occupancy of Types II and III construction may exceed that set forth in Table No. I of this ...
Page 246
... automatic sprinklers shall be installed as specified in this Chapter in the following places : 1. In the cellar of ... sprinkler system required by this Code shall comply in all respects with the " Regulations of the National Board of Fire ...
... automatic sprinklers shall be installed as specified in this Chapter in the following places : 1. In the cellar of ... sprinkler system required by this Code shall comply in all respects with the " Regulations of the National Board of Fire ...
Page 250
... automatic sprinkler system as specified by this Code , or where the cellars or basements are used for banking purposes , safe deposit vaults or similar uses . All basement pipe inlets shall be of cast iron , steel , brass or bronze with ...
... automatic sprinkler system as specified by this Code , or where the cellars or basements are used for banking purposes , safe deposit vaults or similar uses . All basement pipe inlets shall be of cast iron , steel , brass or bronze with ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood