Page 23
International Conference of Building Officials, Pacific Coast Building Officials Conference. No building construction , alteration , repair or demolition requiring a building ... structure beyond the point indicated in each successive inspec- ...
International Conference of Building Officials, Pacific Coast Building Officials Conference. No building construction , alteration , repair or demolition requiring a building ... structure beyond the point indicated in each successive inspec- ...
Page 24
... design and construction of the structure to which he is assigned by the Building Inspector and he shall be thoroughly familiar with the requirements of this Code applying to that building or structure and with their practical application .
... design and construction of the structure to which he is assigned by the Building Inspector and he shall be thoroughly familiar with the requirements of this Code applying to that building or structure and with their practical application .
Page 187
... Building Inspector . No structural steel , cast steel and cast iron shall be used in any building or structure which does not comply with the above requirements or for which no test results have been filed with the Building Inspector ...
... Building Inspector . No structural steel , cast steel and cast iron shall be used in any building or structure which does not comply with the above requirements or for which no test results have been filed with the Building Inspector ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood