Uniform Building CodePacific Coast Building Officials Conference, 1940 - Building laws |
From inside the book
Results 1-3 of 53
Page 226
... ceiling joists and a complete truss is formed , the span shall be con- sidered as the distance between intersecting points of trussing . Roof framing and trussing shall be thoroughly and effectively angle braced . Roof joists when ...
... ceiling joists and a complete truss is formed , the span shall be con- sidered as the distance between intersecting points of trussing . Roof framing and trussing shall be thoroughly and effectively angle braced . Roof joists when ...
Page 304
... ceiling and each portion thereof shall be constructed and supported as hereinafter in this Section provided . The main runners or other supports for any suspended ceiling shall consist of steel channels , steel angles or steel tees ...
... ceiling and each portion thereof shall be constructed and supported as hereinafter in this Section provided . The main runners or other supports for any suspended ceiling shall consist of steel channels , steel angles or steel tees ...
Page 305
... ceiling in the event that such other material or method of construction is the equivalent of the material or method ... ceiling , and each portion thereof , shall be constructed so as to be capable of sustaining a live load of not less ...
... ceiling in the event that such other material or method of construction is the equivalent of the material or method ... ceiling , and each portion thereof , shall be constructed so as to be capable of sustaining a live load of not less ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood