Page 152
... concrete . Water vent pipes and drains shall be filled by grouting or otherwise , after the concrete has hardened thoroughly . ( d ) Transporting Concrete . Concrete shall be handled from the mixer to the place of final deposit as ...
... concrete . Water vent pipes and drains shall be filled by grouting or otherwise , after the concrete has hardened thoroughly . ( d ) Transporting Concrete . Concrete shall be handled from the mixer to the place of final deposit as ...
Page 181
... concrete above the base for the transfer of load from reinforced con- crete section of the column by means of bond on the vertical reinforcement and by direct compression on the concrete . Trans- fer of loads to the metal core shall be ...
... concrete above the base for the transfer of load from reinforced con- crete section of the column by means of bond on the vertical reinforcement and by direct compression on the concrete . Trans- fer of loads to the metal core shall be ...
Page 262
... concrete 2 2 12 1 Grade B concrete Gunite 3 22 12 2 12 1 34 Steel or Cast Iron Col - Brick of clay , shale , con- crete or sand - lin.e umns ; Projecting Steel Beam or Girder Clay tile , clay tile and Flanges ; All Members concrete or ...
... concrete 2 2 12 1 Grade B concrete Gunite 3 22 12 2 12 1 34 Steel or Cast Iron Col - Brick of clay , shale , con- crete or sand - lin.e umns ; Projecting Steel Beam or Girder Clay tile , clay tile and Flanges ; All Members concrete or ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood