Page 27
... Construction . Alternate The provisions of this Code are not intended to prevent the use of Materials types of construction or materials offered as an alternate for the and Types types of construction or materials required by this Code ...
... Construction . Alternate The provisions of this Code are not intended to prevent the use of Materials types of construction or materials offered as an alternate for the and Types types of construction or materials required by this Code ...
Page 50
... construction . Stairs and corridors in Group C occupancies shall be of not less than one - hour fire - resistive construction . A side or rear yard which is forty feet ( 40 ′ ) or more in width to the adjacent property line or to ...
... construction . Stairs and corridors in Group C occupancies shall be of not less than one - hour fire - resistive construction . A side or rear yard which is forty feet ( 40 ′ ) or more in width to the adjacent property line or to ...
Page 75
... CONSTRUCTION CHAPTER 17 - CLASSIFICATION OF ALL BUILDINGS BY TYPES OF CONSTRUCTION Sec . 1701. The requirements of Part V are the minimum re- quirements for the various Types of Construction . In order that a building may be classed in ...
... CONSTRUCTION CHAPTER 17 - CLASSIFICATION OF ALL BUILDINGS BY TYPES OF CONSTRUCTION Sec . 1701. The requirements of Part V are the minimum re- quirements for the various Types of Construction . In order that a building may be classed in ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood