Uniform Building CodePacific Coast Building Officials Conference, 1940 - Building laws |
From inside the book
Results 1-3 of 4
Page 143
... that more than one piece of lumber is necessary , there shall be two thicknesses of one - inch ( 1 " ) ma- terial with joints broken . 1 Foundation Ventilation Wood Diaphragms Termite Provisions Sec . 2527. The 143 Sections 2524-2526.
... that more than one piece of lumber is necessary , there shall be two thicknesses of one - inch ( 1 " ) ma- terial with joints broken . 1 Foundation Ventilation Wood Diaphragms Termite Provisions Sec . 2527. The 143 Sections 2524-2526.
Page 144
... diaphragm under assumed design loads , data from actual tests of diaphragms corresponding to the type proposed may be used or an analogy may be drawn from data furnished in an article entitled " Tests Indicate Design Methods for Earth ...
... diaphragm under assumed design loads , data from actual tests of diaphragms corresponding to the type proposed may be used or an analogy may be drawn from data furnished in an article entitled " Tests Indicate Design Methods for Earth ...
Page 368
... Diaphragms Firestops - required Floors - laminated General requirements 2520 2516 2522 2505 .2505 , 2515 2506 2516 2507 2522 2528 2526 2523 2501 Horizontal members - framing details 2517 Horizontal shear 2504 Joists Piles of .2517-22 ...
... Diaphragms Firestops - required Floors - laminated General requirements 2520 2516 2522 2505 .2505 , 2515 2506 2516 2507 2522 2528 2526 2523 2501 Horizontal members - framing details 2517 Horizontal shear 2504 Joists Piles of .2517-22 ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood