Page 78
... floors of those materials in combination with structural steel or iron or reinforced concrete ; or such floor panel construc- tion shall consist of any floor system providing not less than two - hour fire - resistive construction as ...
... floors of those materials in combination with structural steel or iron or reinforced concrete ; or such floor panel construc- tion shall consist of any floor system providing not less than two - hour fire - resistive construction as ...
Page 83
... floor , balcony or gallery , fire - protection of all members of the roof construction may be omitted . 4. Where the structural steel framework of the roof of a Group A , B or C occupancy is more than eighteen feet ( 18 ' ) and less ...
... floor , balcony or gallery , fire - protection of all members of the roof construction may be omitted . 4. Where the structural steel framework of the roof of a Group A , B or C occupancy is more than eighteen feet ( 18 ' ) and less ...
Page 117
... floor area shall be per- mitted as noted in the following schedule . This reduction shall not be carried into the columns nor shall such reduction be used in design of buildings to be used or occupied as warehouses or for storage ...
... floor area shall be per- mitted as noted in the following schedule . This reduction shall not be carried into the columns nor shall such reduction be used in design of buildings to be used or occupied as warehouses or for storage ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood