Page 106
... FURNACE With FINGER - TIP Gas Control High , Medium , Low and Off . They are made in both floor type and single and dual wall types . THE PICTURE BELOW SHOWS ANDREWS VENTILATING CONCEALED WALL TYPE UNIT A NEW AND DIFFERENT HEATING UNIT ...
... FURNACE With FINGER - TIP Gas Control High , Medium , Low and Off . They are made in both floor type and single and dual wall types . THE PICTURE BELOW SHOWS ANDREWS VENTILATING CONCEALED WALL TYPE UNIT A NEW AND DIFFERENT HEATING UNIT ...
Page 241
... furnaces , but the distance to the partitions at the side may be reduced to two feet ( 2 ′ ) if they are covered with sheet metal or metal lath and plaster . The distance from the top shield of such furnace to any ceiling or framing of ...
... furnaces , but the distance to the partitions at the side may be reduced to two feet ( 2 ′ ) if they are covered with sheet metal or metal lath and plaster . The distance from the top shield of such furnace to any ceiling or framing of ...
Page 244
... furnaces and other heating or power apparatus in which oil burners are installed shall be constructed and erected as required for similar apparatus using solid fuel . Oil burning apparatus using commercial fuel oil , furnace oil ...
... furnaces and other heating or power apparatus in which oil burners are installed shall be constructed and erected as required for similar apparatus using solid fuel . Oil burning apparatus using commercial fuel oil , furnace oil ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood