Uniform Building CodePacific Coast Building Officials Conference, 1940 - Building laws |
From inside the book
Results 1-3 of 57
Page 87
... iron , rein- Structural forced concrete , masonry or wood and shall be designed and Frame- erected as specified in Chapter 26 for reinforced concrete , Chap- work ter 27 for steel and iron , Chapters 22 and 25 for wood and Chap- ters 24 ...
... iron , rein- Structural forced concrete , masonry or wood and shall be designed and Frame- erected as specified in Chapter 26 for reinforced concrete , Chap- work ter 27 for steel and iron , Chapters 22 and 25 for wood and Chap- ters 24 ...
Page 187
... IRON ( Quality and Design ) Section 2701. The quality and design of all structural steel Quality and iron used in buildings or structures shall conform to the and requirements specified in this Chapter . Structural steel shall be of ...
... IRON ( Quality and Design ) Section 2701. The quality and design of all structural steel Quality and iron used in buildings or structures shall conform to the and requirements specified in this Chapter . Structural steel shall be of ...
Page 240
... iron bracket at- tached to the studs or framework of the building with through- bolts . When erected on the inside of a building such patent chimneys shall be provided with a smokeproof clean - out of ap- proved design at or near the ...
... iron bracket at- tached to the studs or framework of the building with through- bolts . When erected on the inside of a building such patent chimneys shall be provided with a smokeproof clean - out of ap- proved design at or near the ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood