Uniform Building CodePacific Coast Building Officials Conference, 1940 - Building laws |
From inside the book
Results 1-3 of 44
Page 266
... lath ) not less than three - eighths inch ( % " ) in thickness and having not more than 15 per cent of combustible material combined with the gypsum may be sub- stituted in interior construction for metal lath for resistance periods of ...
... lath ) not less than three - eighths inch ( % " ) in thickness and having not more than 15 per cent of combustible material combined with the gypsum may be sub- stituted in interior construction for metal lath for resistance periods of ...
Page 302
International Conference of Building Officials, Pacific Coast Building Officials Conference. Wood Lath Gypsum Plaster Lath Inspector or his deputy to make holes in the wall for the pur- pose of determining the thickness of the plaster ...
International Conference of Building Officials, Pacific Coast Building Officials Conference. Wood Lath Gypsum Plaster Lath Inspector or his deputy to make holes in the wall for the pur- pose of determining the thickness of the plaster ...
Page 304
... lath in place shall be driven to ap- proximately three - fourths penetration and bent over one or more strands or their equivalent of such metal lath . Staples , furring nails , furring clips , or other methods of fastening metal lath ...
... lath in place shall be driven to ap- proximately three - fourths penetration and bent over one or more strands or their equivalent of such metal lath . Staples , furring nails , furring clips , or other methods of fastening metal lath ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood