Uniform Building CodePacific Coast Building Officials Conference, 1940 - Building laws |
From inside the book
Results 1-3 of 78
Page 94
... less in width than the wall framing supported thereon , and of the quality required in Section 2204 shall be placed ... less than five - eighths inch ( % " ) thick . Approved fiber board not less than seven - sixteenths inch ( 7/16 ...
... less in width than the wall framing supported thereon , and of the quality required in Section 2204 shall be placed ... less than five - eighths inch ( % " ) thick . Approved fiber board not less than seven - sixteenths inch ( 7/16 ...
Page 95
... less ( Con't ) in width and not less than three such nails when such sheathing boards exceed eight inches ( 8 " ) in width . In all cases , except where the building is not intended for human occupancy , or where the interior face of ...
... less ( Con't ) in width and not less than three such nails when such sheathing boards exceed eight inches ( 8 " ) in width . In all cases , except where the building is not intended for human occupancy , or where the interior face of ...
Page 142
... less shall consist of not less than two - inch by four - inch ( 2 " x4 " ) studs ; for buildings of three stories , the studding shall be not less than three - inch by four- inch ( 3 " x4 " ) or two - inch by six - inch ( 2 ′′ x6 ...
... less shall consist of not less than two - inch by four - inch ( 2 " x4 " ) studs ; for buildings of three stories , the studding shall be not less than three - inch by four- inch ( 3 " x4 " ) or two - inch by six - inch ( 2 ′′ x6 ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood