Uniform Building CodePacific Coast Building Officials Conference, 1940 - Building laws |
From inside the book
Results 1-3 of 56
Page 37
... of not less than three - hour fire - resistive construction as specified in Chap- ters 42 and 43. All openings in walls forming such separation shall be protected on each side thereof by self - closing one - hour fire - resistive doors ...
... of not less than three - hour fire - resistive construction as specified in Chap- ters 42 and 43. All openings in walls forming such separation shall be protected on each side thereof by self - closing one - hour fire - resistive doors ...
Page 50
... of not less than one - hour fire - resistive construction . A side or rear yard which is forty feet ( 40 ′ ) or more in width to the adjacent property line or to another building , and which affords unobstructed access to a street , may be ...
... of not less than one - hour fire - resistive construction . A side or rear yard which is forty feet ( 40 ′ ) or more in width to the adjacent property line or to another building , and which affords unobstructed access to a street , may be ...
Page 51
... than those of open frame construction , when more than one story in height or two hundred square feet ( 200 sq . ft . ) in area , shall have exterior walls , bearing partitions and floors of not less than one - hour fire - resistive ...
... than those of open frame construction , when more than one story in height or two hundred square feet ( 200 sq . ft . ) in area , shall have exterior walls , bearing partitions and floors of not less than one - hour fire - resistive ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood