Uniform Building CodePacific Coast Building Officials Conference, 1940 - Building laws |
From inside the book
Results 1-3 of 22
Page 115
... Live Load . The live load includes all loads except dead and lateral loads . Sec . 2302. ( a ) General . Buildings and all parts thereof shall Loads be of sufficient strength to support the estimated or actual imposed dead and live loads ...
... Live Load . The live load includes all loads except dead and lateral loads . Sec . 2302. ( a ) General . Buildings and all parts thereof shall Loads be of sufficient strength to support the estimated or actual imposed dead and live loads ...
Page 117
... live loads Reduction shall be permitted in designing of columns , piers , walls , founda- of Live tions , trusses and girders . 1. No reduction of the assumed live load shall be allowed in the design of any slabs , joists or beams . 2 ...
... live loads Reduction shall be permitted in designing of columns , piers , walls , founda- of Live tions , trusses and girders . 1. No reduction of the assumed live load shall be allowed in the design of any slabs , joists or beams . 2 ...
Page 118
International Conference of Building Officials, Pacific Coast Building Officials Conference. Live Loads and Seating ... load resisting moment . The weight of earth superimposed over footings may be used to calculate the dead load ...
International Conference of Building Officials, Pacific Coast Building Officials Conference. Live Loads and Seating ... load resisting moment . The weight of earth superimposed over footings may be used to calculate the dead load ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood