Uniform Building CodePacific Coast Building Officials Conference, 1940 - Building laws |
From inside the book
Results 1-3 of 86
Page 29
... permitted , and upon the conviction of any such violation such person shall be punishable by a fine of not more than ... permit or approval of plans and specifications shall not be deemed or construed to be a permit for , or an approval ...
... permitted , and upon the conviction of any such violation such person shall be punishable by a fine of not more than ... permit or approval of plans and specifications shall not be deemed or construed to be a permit for , or an approval ...
Page 98
... permitted in this code . Sec . 2214. Any projections from the building shall conform to the requirements for exterior walls , as required in Chapter 45 . Sec . 2215. Penthouses and skylights may be of any mate- rial permitted in ...
... permitted in this code . Sec . 2214. Any projections from the building shall conform to the requirements for exterior walls , as required in Chapter 45 . Sec . 2215. Penthouses and skylights may be of any mate- rial permitted in ...
Page 133
... permitted for a square col- umn of the same cross - sectional area . Sec . 2506. Members subject to both axial and bending stresses Combined shall be proportioned in accordance with the following formula : Stresses P / A M / S + equals ...
... permitted for a square col- umn of the same cross - sectional area . Sec . 2506. Members subject to both axial and bending stresses Combined shall be proportioned in accordance with the following formula : Stresses P / A M / S + equals ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood