Uniform Building CodePacific Coast Building Officials Conference, 1940 - Building laws |
From inside the book
Results 1-3 of 43
Page 239
... pipe with such sleeves or flanges separating the outer pipe at least one - half inch ( 1⁄2 " ) from the clay or concrete vent . The area of any flue or vent shall be not less than the area of the largest vent connection inlet plus 50 ...
... pipe with such sleeves or flanges separating the outer pipe at least one - half inch ( 1⁄2 " ) from the clay or concrete vent . The area of any flue or vent shall be not less than the area of the largest vent connection inlet plus 50 ...
Page 249
... pipes from pressure tanks shall extend two inches ( 2 " ) into and above the bottom of such tanks . All tanks shall be equipped with a manhole , ladder and platform , drain pipe , water and pressure gauges . Every pressure tank shall be ...
... pipes from pressure tanks shall extend two inches ( 2 " ) into and above the bottom of such tanks . All tanks shall be equipped with a manhole , ladder and platform , drain pipe , water and pressure gauges . Every pressure tank shall be ...
Page 250
... pipe inlets shall be installed in the first floor of every store , warehouse or factory where there are cellars or basements under same , except where in such cellars or basements there is installed an automatic sprinkler system as ...
... pipe inlets shall be installed in the first floor of every store , warehouse or factory where there are cellars or basements under same , except where in such cellars or basements there is installed an automatic sprinkler system as ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood