Uniform Building CodePacific Coast Building Officials Conference, 1940 - Building laws |
From inside the book
Results 1-3 of 49
Page 79
... similar projections shall be con- Projections structed of incombustible materials with walls , floors and roofs as specified in this Chapter and as specified in Chapter 35 . Porches and exterior balconies shall be constructed of incom ...
... similar projections shall be con- Projections structed of incombustible materials with walls , floors and roofs as specified in this Chapter and as specified in Chapter 35 . Porches and exterior balconies shall be constructed of incom ...
Page 88
... similar projections shall be con- structed of incombustible materials with walls , floors and roof as required in this Chapter and in Chapter 35 . Porches and exterior balconies shall be constructed of incom- bustible inaterials but ...
... similar projections shall be con- structed of incombustible materials with walls , floors and roof as required in this Chapter and in Chapter 35 . Porches and exterior balconies shall be constructed of incom- bustible inaterials but ...
Page 285
... similar rooms not having fixed seats and the capac- ity unit therefor shall be thirty square feet ( 30 sq . ft . ) . ( d ) Group 4 shall be the same as Group 3 but having fixed seats and the capacity unit therefor shall be forty square ...
... similar rooms not having fixed seats and the capac- ity unit therefor shall be thirty square feet ( 30 sq . ft . ) . ( d ) Group 4 shall be the same as Group 3 but having fixed seats and the capacity unit therefor shall be forty square ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood