... slope of not more than one in 10 . The foyer if not abutting directly upon a public street shall communicate therewith by a straight and unobstructed corridor or passageway equal in width to that required for the main en- trance which ...
... slope of not more than one in 10 . The foyer if not abutting directly upon a public street shall communicate therewith by a straight and unobstructed corridor or passageway equal in width to that required for the main en- trance which ...
Page 43
... slope of not more than one in five . Ramps steeper than one in eight shall have non - slip floor surfaces . Aisles in balconies or galleries shall be located so that there are not more than six seats between any seat and an aisle ...
... slope of not more than one in five . Ramps steeper than one in eight shall have non - slip floor surfaces . Aisles in balconies or galleries shall be located so that there are not more than six seats between any seat and an aisle ...
Page 92
... slope along and in the length of any side of such building but in no case shall such height exceed forty - five feet ... slopes more than one foot ( 1 ' ) in ten feet ( 10 ' ) shall be level or shall be stepped so that both top and ...
... slope along and in the length of any side of such building but in no case shall such height exceed forty - five feet ... slopes more than one foot ( 1 ' ) in ten feet ( 10 ' ) shall be level or shall be stepped so that both top and ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood