Page 208
... Solid Masonry Walls Working Stresses Thickness of Exter- ior Walls Other Than Skeleton Construc- tion CHAPTER 29 - WALLS AND PARTITIONS ( Solid Masonry Walls ) Sec . 2901. Solid masonry walls shall be supported at right angles to the ...
... Solid Masonry Walls Working Stresses Thickness of Exter- ior Walls Other Than Skeleton Construc- tion CHAPTER 29 - WALLS AND PARTITIONS ( Solid Masonry Walls ) Sec . 2901. Solid masonry walls shall be supported at right angles to the ...
Page 209
... Solid masonry exterior bearing or party walls con- structed as specified in part ( d ) of this Section may be of lesser thickness . ( b ) Non - Bearing Walls . Non - bearing walls of solid ma- sonry shall be not less in thickness than ...
... Solid masonry exterior bearing or party walls con- structed as specified in part ( d ) of this Section may be of lesser thickness . ( b ) Non - Bearing Walls . Non - bearing walls of solid ma- sonry shall be not less in thickness than ...
Page 366
... Solid masonry - bond Solid masonry - chases and recesses Solid masonry - fire - resistive classification Solid masonry - foundation walls Solid masonry - general provisions .. 2915 2914 2936 2904 2906 4302 2938 2901 , 2932 Solid masonry ...
... Solid masonry - bond Solid masonry - chases and recesses Solid masonry - fire - resistive classification Solid masonry - foundation walls Solid masonry - general provisions .. 2915 2914 2936 2904 2906 4302 2938 2901 , 2932 Solid masonry ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood