Uniform Building CodePacific Coast Building Officials Conference, 1940 - Building laws |
From inside the book
Results 1-3 of 75
Page 71
... space termed in this Code a private Exceptions garage is provided in any building of mixed occupancies , such and storage space shall be limited to six hundred and fifty square Deviations feet ( 650 sq . ft . ) of floor area unless such ...
... space termed in this Code a private Exceptions garage is provided in any building of mixed occupancies , such and storage space shall be limited to six hundred and fifty square Deviations feet ( 650 sq . ft . ) of floor area unless such ...
Page 226
... space which are not less than eighteen inches ( 18 " ) square . In wood frame roof construction where ceilings occur the attic spaces or spaces between ceilings and the under side of roofs shall be divided into horizontal areas of not ...
... space which are not less than eighteen inches ( 18 " ) square . In wood frame roof construction where ceilings occur the attic spaces or spaces between ceilings and the under side of roofs shall be divided into horizontal areas of not ...
Page 276
... space shall not exceed one - third the width of the street , meas- ured between curbs , and in no case shall the space within five feet ( 5 ' ) of the nearest rail of any railway tracks be occu- pied for building materials . The sidewalk ...
... space shall not exceed one - third the width of the street , meas- ured between curbs , and in no case shall the space within five feet ( 5 ' ) of the nearest rail of any railway tracks be occu- pied for building materials . The sidewalk ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood