Uniform Building CodePacific Coast Building Officials Conference, 1940 - Building laws |
From inside the book
Results 1-3 of 83
Page 76
... specified in Section 1813 shall be of fire - resistive construction . Note : Fire - resistive materials and fire - resistive construc- tion have a specific meaning in this Code , as specified in Chapters 42 and 43 . Sec . 1802. The ...
... specified in Section 1813 shall be of fire - resistive construction . Note : Fire - resistive materials and fire - resistive construc- tion have a specific meaning in this Code , as specified in Chapters 42 and 43 . Sec . 1802. The ...
Page 86
... CHAPTER 20 - TYPE III BUILDINGS ( Ordinary Masonry ) Sec . 2001. In " Type III Buildings , " the interior load ... specified in Chapter 29 shall be provided , and shall be not less than four - hour fire - resistive construction as ...
... CHAPTER 20 - TYPE III BUILDINGS ( Ordinary Masonry ) Sec . 2001. In " Type III Buildings , " the interior load ... specified in Chapter 29 shall be provided , and shall be not less than four - hour fire - resistive construction as ...
Page 87
... specified in Chapter 26 for reinforced concrete , Chap- work ter 27 for steel and iron , Chapters 22 and 25 for wood and Chap- ters 24 and 29 for masonry . Sec . 2009. Fire - protection of steel , iron , or wood structural Fire members ...
... specified in Chapter 26 for reinforced concrete , Chap- work ter 27 for steel and iron , Chapters 22 and 25 for wood and Chap- ters 24 and 29 for masonry . Sec . 2009. Fire - protection of steel , iron , or wood structural Fire members ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood