Uniform Building CodePacific Coast Building Officials Conference, 1940 - Building laws |
From inside the book
Results 1-3 of 71
Page 49
... story in height , churches , lodges , clubs , museums , dance halls , armories , libraries , gymnasiums , passenger stations , administration buildings of city , county or state and similar buildings having a permanent stage and hav ...
... story in height , churches , lodges , clubs , museums , dance halls , armories , libraries , gymnasiums , passenger stations , administration buildings of city , county or state and similar buildings having a permanent stage and hav ...
Page 62
... Stories 1 street 2 streets 3 or more streets Type I NO RESTRICTIONS 6 or 7 stories 12,000 15,000 18,000 Type II 2 to 5 stories 15,000 18,000 20,000 1 story 20,000 25,000 30,000 2 to 5 stories 12,000 15,000 18,000 Type III 1 story 18,000 ...
... Stories 1 street 2 streets 3 or more streets Type I NO RESTRICTIONS 6 or 7 stories 12,000 15,000 18,000 Type II 2 to 5 stories 15,000 18,000 20,000 1 story 20,000 25,000 30,000 2 to 5 stories 12,000 15,000 18,000 Type III 1 story 18,000 ...
Page 66
... story 20,000 25,000 30,000 2 to 5 stories 12,000 15,000 18,000 Type III 1 story 18,000 20,000 22,500 2 or 3 stories 9,000 10,000 12,000 Type IV 1 story * 9,000 10,000 12,000 2 or 3 stories 6,000 7,000 Type V 8,000 1 story 8,000 9,000 ...
... story 20,000 25,000 30,000 2 to 5 stories 12,000 15,000 18,000 Type III 1 story 18,000 20,000 22,500 2 or 3 stories 9,000 10,000 12,000 Type IV 1 story * 9,000 10,000 12,000 2 or 3 stories 6,000 7,000 Type V 8,000 1 story 8,000 9,000 ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood