Uniform Building CodePacific Coast Building Officials Conference, 1940 - Building laws |
From inside the book
Results 1-3 of 57
Page 40
... street fronts , of Group A occupancies which are less than five feet ( 5 ' ) from adjacent property lines shall have no openings therein . All openings in exterior walls , except on street fronts , which are less than ten feet ( 10 ...
... street fronts , of Group A occupancies which are less than five feet ( 5 ' ) from adjacent property lines shall have no openings therein . All openings in exterior walls , except on street fronts , which are less than ten feet ( 10 ...
Page 41
... street front which shall serve as the main Exit entrance shall be proportioned on the basis of two feet ( 2 ' ) of ... street adjacent thereto shall be by ramps with a slope of not more than one in 10 . The foyer if not abutting directly ...
... street front which shall serve as the main Exit entrance shall be proportioned on the basis of two feet ( 2 ' ) of ... street adjacent thereto shall be by ramps with a slope of not more than one in 10 . The foyer if not abutting directly ...
Page 276
... street , meas- ured between curbs , and in no case shall the space within five feet ( 5 ' ) of the nearest rail of ... street . Building materials may be placed in front of the property adjoining a building site under the same conditions ...
... street , meas- ured between curbs , and in no case shall the space within five feet ( 5 ' ) of the nearest rail of ... street . Building materials may be placed in front of the property adjoining a building site under the same conditions ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood