Page 119
... Tile . 3. Gypsum Block or Tile . 4. Hollow Clay Tile . 5. Stone . 6. Concrete - Plain , 7. Gypsum - Plain poured * . * Note : This applies only to gypsum used in roof construction , non - bearing walls or partitions , fire - protection ...
... Tile . 3. Gypsum Block or Tile . 4. Hollow Clay Tile . 5. Stone . 6. Concrete - Plain , 7. Gypsum - Plain poured * . * Note : This applies only to gypsum used in roof construction , non - bearing walls or partitions , fire - protection ...
Page 120
... Tile Plain Concrete Cast Stone Sec . 2405. Hollow clay tile used for exterior walls and bear- ing walls shall meet the requirements for the " 5-16 " clay tile given in the " Standard Specifications and Tests for Structural Clay Load ...
... Tile Plain Concrete Cast Stone Sec . 2405. Hollow clay tile used for exterior walls and bear- ing walls shall meet the requirements for the " 5-16 " clay tile given in the " Standard Specifications and Tests for Structural Clay Load ...
Page 274
... tile securely fastened with copper nails or cop- per wire ; provided that for roofs not exceeding a rise of eight inches ( 8 " ) in twelve inches ( 12 ′′ ) , galvanized iron nails may be used , and provided further that tile with ...
... tile securely fastened with copper nails or cop- per wire ; provided that for roofs not exceeding a rise of eight inches ( 8 " ) in twelve inches ( 12 ′′ ) , galvanized iron nails may be used , and provided further that tile with ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood