Uniform Building CodePacific Coast Building Officials Conference, 1940 - Building laws |
From inside the book
Results 1-3 of 49
Page 234
... wire glass is required , it shall mean glass the thickness of which at the thinnest point shall be not less than one - fourth inch ( 4 " ) and in which a wire netting is embedded . glass shall be set with putty and metal stops . Wire ...
... wire glass is required , it shall mean glass the thickness of which at the thinnest point shall be not less than one - fourth inch ( 4 " ) and in which a wire netting is embedded . glass shall be set with putty and metal stops . Wire ...
Page 304
... wire hangers not smaller than No. 8 W. & M. gauge spaced at not more than four feet ( 4 ' ) on center . Wire hangers shall be securely fastened to the structural fram- ing , masonry or concrete with approved metal clips or approved ...
... wire hangers not smaller than No. 8 W. & M. gauge spaced at not more than four feet ( 4 ' ) on center . Wire hangers shall be securely fastened to the structural fram- ing , masonry or concrete with approved metal clips or approved ...
Page 306
... wire netting , expanded metal fabric or welded wire fabric shall weigh not less than one and five - tenths pounds per square yard . When woven wire netting is used it shall be not less than No. 16 W. & M. gauge wire ; provided , however ...
... wire netting , expanded metal fabric or welded wire fabric shall weigh not less than one and five - tenths pounds per square yard . When woven wire netting is used it shall be not less than No. 16 W. & M. gauge wire ; provided , however ...
Other editions - View all
Common terms and phrases
A. S. T. M. Designation approved asbestos bars beams bolts brick Building Inspector building or structure ceiling cent Chapter 43 chimney coat Code column compression compression members construction as specified diameter doors Douglas Fir dry standpipes Enclosure exceed exit exterior walls Fire Zone fire-protected flange floor area foot four inches frame girders grade Group I occupancies gypsum horizontal incombustible materials joists least less than one-hour live load located lumber maximum metal lath minimum mortar one-half inch one-hour fire-resistive construction panel partitions permitted pipe plaster plate portland cement pounds per square proscenium protected reinforced concrete rivets roof shear side six inches smoke pipe solid masonry space span specified in Chapter specified in Section square feet square inch stairs stairways standpipes street structural steel stucco studs tests thickness tion total band twelve inches 12 Types of Construction unit stress Vertical Openings width wire wood