Physical Principles and Techniques of Protein Chemistry, Part 2Sydney J. Leach, Sidney J. Leach Physical Principles and Techniques of Protein Chemistry, Part B deals with the theories and application of selected physical methods in protein chemistry evaluation. This book is divided into seven chapters that cover the ultracentrifugal analysis, light scattering, infrared (IR) methods, nuclear magnetic resonance (NMR) spectroscopy, and differential thermal analysis of protein properties. This text first describes the fundamental ideas and methodology of sedimentation analysis of ideal noninteracting solutes and the problems of nonideality and solute-solute interaction. This book then deals ... |
From inside the book
Results 1-3 of 31
Page 189
... filters can be held in the " white light " beam of the Brice instrument and the filtrates checked visually for dust . Cleaning of these filters is done by soaking in HNO3 - H2SO4 , followed by exhaustive flushing of the disk with clean ...
... filters can be held in the " white light " beam of the Brice instrument and the filtrates checked visually for dust . Cleaning of these filters is done by soaking in HNO3 - H2SO4 , followed by exhaustive flushing of the disk with clean ...
Page 193
... filters . To eliminate the division , which is slow on a desk . calculator , the inverse transmittances may be tabulated and the reading ratio multiplied by 1 / T = " filter factor " . The result is G90 / Go in the Brice et al . ( 1950 ) ...
... filters . To eliminate the division , which is slow on a desk . calculator , the inverse transmittances may be tabulated and the reading ratio multiplied by 1 / T = " filter factor " . The result is G90 / Go in the Brice et al . ( 1950 ) ...
Page 203
... filters . This factor is applied to the denominator of Eq . ( 3 ) for convenience , since 0 ° readings are generally taken with all filters in the beam ( see Sec- tion I , D and below ) . If a digital readout galvanometer such as ...
... filters . This factor is applied to the denominator of Eq . ( 3 ) for convenience , since 0 ° readings are generally taken with all filters in the beam ( see Sec- tion I , D and below ) . If a digital readout galvanometer such as ...
Contents
Ultracentrifugal Analysis J H Coates | 1 |
Glossary of Symbols | 2 |
Introduction | 3 |
Copyright | |
47 other sections not shown
Other editions - View all
Common terms and phrases
absorption acid amino anions atoms axial ratio band beam binding Biol bond Bradbury calculated capillary cell centrifugal chain changes Chem chemical shifts complex component concentration constant copper(II denaturation density gradient dependence determined dilution Doty effect electron ellipsoid enzyme equation extrapolation field Fraser frequency fringe Gurd histidine hydrogen ion imidazole imidazole groups instrument interaction intrinsic viscosity Jardetzky length light scattering light-scattering line width lysozyme macromolecule magnetic measured meniscus metal ion method molecular weight molecule myoglobin nuclei observed obtained optical density optical system partial specific volume particle PBLG peak peptide Phys plot Polymer Sci Proc protein solution protons random coil Rayleigh reference refractive index relaxation residues resonance RNase rotation rotor sample schlieren Section sedimentation coefficient sedimentation equilibrium shearing stress slit solvent spectra spectrum speed structure studies Tanford technique temperature Timasheff tion transition ultracentrifuge values velocity Vinograd viscometer zero zone