Relationship of the Nuclear Regulatory Commission to the Nuclear Industry: Oversight Hearing Before the Subcommittee on General Oversightand Investigations of the Committee on Interior and Insular Affairs, House of Representatives, One Hundredth Congress, First Session ... Hearing Held in Washington, DC, June 11, 1987, Volume 4 |
From inside the book
Results 1-5 of 27
Page 467
... rods out of sequence . The result of that out - of - sequence rod pull caused the reactor to experi- ence a premature criticality , which meant that a sustained chain reaction was achieved much earlier than anticipated . When that ...
... rods out of sequence . The result of that out - of - sequence rod pull caused the reactor to experi- ence a premature criticality , which meant that a sustained chain reaction was achieved much earlier than anticipated . When that ...
Page 476
... RODS OUT OF SEQUENCE . THE RESULT OF THAT OUT OF SEQUENCE ROD PULL CAUSED THE REACTOR TO EXPERIENCE A PREMATURE CRITICALITY , WHICH MEANT THAT A SUSTAINED CHAIN REACTION WAS ACHIEVED MUCH EARLIER THAN ANTICIPATED . WHEN THAT OCCURRED ...
... RODS OUT OF SEQUENCE . THE RESULT OF THAT OUT OF SEQUENCE ROD PULL CAUSED THE REACTOR TO EXPERIENCE A PREMATURE CRITICALITY , WHICH MEANT THAT A SUSTAINED CHAIN REACTION WAS ACHIEVED MUCH EARLIER THAN ANTICIPATED . WHEN THAT OCCURRED ...
Page 502
... rod pull error and stated , contrary to the advice of a nuclear consultant and one of their reactor engineers , that the error did not result in reactor criticality . DECO did advise that reactor engineering was performing a review of ...
... rod pull error and stated , contrary to the advice of a nuclear consultant and one of their reactor engineers , that the error did not result in reactor criticality . DECO did advise that reactor engineering was performing a review of ...
Page 506
... rod pull to criticality on the actual Fermi 2 reactor . His only other experience had been in the Fermi 2 simulator . When KLINE began withdrawing the first group 3 rods , he did not observe the procedure instruction to pull from 00-04 ...
... rod pull to criticality on the actual Fermi 2 reactor . His only other experience had been in the Fermi 2 simulator . When KLINE began withdrawing the first group 3 rods , he did not observe the procedure instruction to pull from 00-04 ...
Page 507
... rod pull error ; however , he did not mention the Reactor Engineering Log entry . At 8:00 a.m. , during the DECO staff meeting , PRESTON gave the DER to the Assistant Plant Superintendent , Gregg OVERBECK , who read the DER and stated ...
... rod pull error ; however , he did not mention the Reactor Engineering Log entry . At 8:00 a.m. , during the DECO staff meeting , PRESTON gave the DER to the Assistant Plant Superintendent , Gregg OVERBECK , who read the DER and stated ...
Other editions - View all
Common terms and phrases
68 Stat access to protected access to vital agency alcohol abuse amended 42 U.S.C. Appendix applicant or licensee Bernthal Browns Ferry Chairman DEFAZIO develop discussion document drug abuse drug and alcohol duty programs Edison Electric Institute effective Enclosure enforcement action ensure evaluation facility Federal Register Fermi final rule fire protection fire protection engineers fitness for duty GEJDENSON guidelines health and safety implementation incidents INPO inspection interpretation issued under sec July Lenart licensee's material false statement meeting Memorandum NRC staff NRC's nuclear industry nuclear power plant Nuclear Regulatory Commission nuclear utility NUMARC Office of Investigations Overbeck personnel with unescorted policy statement power plant personnel premature criticality Preston problem proposed rule protected areas reactor engineering Regional regulations request Resident Inspector responsibility rod pull rulemaking significant specific Stello supervisor U.S. Attorney unescorted access vital areas written procedures ZECH