... material means a material which , in the form in which it is used , is either one of the following : 1. Material of which no part will ignite and burn when subjected to fire . Any material conforming to U.B.C. Standard No. 4-1 shall be ...
... material means a material which , in the form in which it is used , is either one of the following : 1. Material of which no part will ignite and burn when subjected to fire . Any material conforming to U.B.C. Standard No. 4-1 shall be ...
Page 84
... materials 10. Corrosive liquids 11. Oxidizing material - gases 12. Oxidizing material - liquids 13. Oxidizing material - solids 14. Organic peroxides 15. Nitromethane ( unstable materials ) 16. Ammonium nitrate 17. Ammonium nitrate ...
... materials 10. Corrosive liquids 11. Oxidizing material - gases 12. Oxidizing material - liquids 13. Oxidizing material - solids 14. Organic peroxides 15. Nitromethane ( unstable materials ) 16. Ammonium nitrate 17. Ammonium nitrate ...
Page 730
... material on which fill is to be placed . BORROW is earth material acquired from an off - site location for use in grading on a site . CIVIL ENGINEER shall mean a professional engineer registered in the state to practice in the field of ...
... material on which fill is to be placed . BORROW is earth material acquired from an off - site location for use in grading on a site . CIVIL ENGINEER shall mean a professional engineer registered in the state to practice in the field of ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength