Uniform Building Code |
From inside the book
Results 1-3 of 77
Page 533
... applied in shingle fashion to drain water . Felts and cap sheets shall be applied in solid uniform moppings of bitumen . 3. Shingle , shake and tile roofs . A. General . Installation shall be in accor- dance with Table No. 32 - B ...
... applied in shingle fashion to drain water . Felts and cap sheets shall be applied in solid uniform moppings of bitumen . 3. Shingle , shake and tile roofs . A. General . Installation shall be in accor- dance with Table No. 32 - B ...
Page 534
... applied to roofs with solid or spaced sheathing . In wind - driven - snow areas sheathing shall be solid and the shakes shall be applied over an underlayment of not less than Type 15 felt . Shakes shall be laid with a side lap of not ...
... applied to roofs with solid or spaced sheathing . In wind - driven - snow areas sheathing shall be solid and the shakes shall be applied over an underlayment of not less than Type 15 felt . Shakes shall be laid with a side lap of not ...
Page 654
... applied over base coats which have been in place for the time periods set forth in Table No. 47 - F . The third or finish coat shall be applied with sufficient material and pressure to bond to and to cover the brown coat and shall be of ...
... applied over base coats which have been in place for the time periods set forth in Table No. 47 - F . The third or finish coat shall be applied with sufficient material and pressure to bond to and to cover the brown coat and shall be of ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength