Uniform Building Code |
From inside the book
Results 1-3 of 16
Page 60
... manufactured , processed , generated or stored ; and pin - refinishing rooms 4 - Repair garages not classified as a Group B , Division 1 Occupancy FIRE RESISTANCE OF EXTERIOR WALLS 1 hour less than 20 feet 1 hour less than 5 feet 2 ...
... manufactured , processed , generated or stored ; and pin - refinishing rooms 4 - Repair garages not classified as a Group B , Division 1 Occupancy FIRE RESISTANCE OF EXTERIOR WALLS 1 hour less than 20 feet 1 hour less than 5 feet 2 ...
Page 208
... Manufacture and Fabrication . The manufacture and fabrication of struc- tural glued - laminated timber shall be in accordance with U.B.C. Standard No. 25-10 . All work shall be under the supervision of qualified personnel . ( g ) ...
... Manufacture and Fabrication . The manufacture and fabrication of struc- tural glued - laminated timber shall be in accordance with U.B.C. Standard No. 25-10 . All work shall be under the supervision of qualified personnel . ( g ) ...
Page 316
... manufactured with exterior glue . " Floor or roof sheathing conforming with this table shall be deemed to meet the design criteria of Section 2516 . TABLE NO . 25 - S - 2 - ALLOWABLE LOADS FOR PLYWOOD ROOF SHEATHING CONTINUOUS OVER TWO ...
... manufactured with exterior glue . " Floor or roof sheathing conforming with this table shall be deemed to meet the design criteria of Section 2516 . TABLE NO . 25 - S - 2 - ALLOWABLE LOADS FOR PLYWOOD ROOF SHEATHING CONTINUOUS OVER TWO ...
Contents
008228 | 19 |
Part Administrative | 25 |
Permits and Inspections | 31 |
Copyright | |
108 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section applied approved bars beam bending bolts building official building or structure ceiling Chapter column compression members computed concrete dead load Decking diameter distance Division 1 Occupancies doors exceed exit exterior walls extreme fiber factor fire-resistive construction fire-resistive rating flange Formula framing gauge girders grade grain Group grout gypsum gypsum plaster height horizontal installed joints joists laminations length less live load located masonry materials maximum minimum modulus of elasticity nails noncombustible occupancy separation occupant load one-hour fire-resistive openings panels permitted perpendicular plastic plywood portland cement pounds per square prestressing protected ratio resist roof rooms Select Structural shear reinforcement shear strength shear stress sheathing side slab smoke detector space span specified in Section splices square feet square inch stairway steel studs surface Table tensile stress tension tests thickness Type U.B.C. Standard units at least values vertical welds width wire wood yield strength