Uniform Building Code: State of California ... amendments, Volume 1California Building Standards Commission, 1989 - Building laws |
From inside the book
Results 1-3 of 87
Page 112-65
... deflection of the structure or parts thereof when such deflections might create unsafe conditions . 2. The ... Deflection . The deflection of any structural members shall not exceed the values set forth in Table No. 23 - D , based upon ...
... deflection of the structure or parts thereof when such deflections might create unsafe conditions . 2. The ... Deflection . The deflection of any structural members shall not exceed the values set forth in Table No. 23 - D , based upon ...
Page 520-37
... deflection . For nonprestressed members , the portion of the mem- ber in compression shall determine whether values in Table No. 26 - D for normal- weight or lightweight concrete shall apply . If deflection is computed , account should ...
... deflection . For nonprestressed members , the portion of the mem- ber in compression shall determine whether values in Table No. 26 - D for normal- weight or lightweight concrete shall apply . If deflection is computed , account should ...
Page 520-116
... deflection readings shall be taken . 6. Test load shall be removed immediately after initial deflection readings , and final deflection readings shall be taken 24 hours after removal of the test load . 7. If the portion of the structure ...
... deflection readings shall be taken . 6. Test load shall be removed immediately after initial deflection readings , and final deflection readings shall be taken 24 hours after removal of the test load . 7. If the portion of the structure ...
Contents
1 | 30-2 |
Part IIIRequirements Based on Occupancy CHAPTER 5 Classification of All Buildings by Use or Occupancy and General Requirements for All Occu... | 42-4 |
Mixed Occupancy | 42-5 |
Copyright | |
51 other sections not shown
Common terms and phrases
accessible accordance addition apply approved building official building or structure CACAC California ceiling cell Code Sections comply concrete conform corridors Curb ramps dead load detectors devices dimension Division 1 Occupancies doors dwelling units elevator enclosures equipment exceed EXCEPTION existing buildings exit exterior walls fire alarm system fire-resistive construction floor area footcandles grab bar Group H grout handwashing fixture hazard height horizontal inmates installed lateral forces least less live load located masonry materials Matrix Adoption Appendix maximum minimum nonbuilding structures noncombustible nursing occupancy separation occupant load one-hour fire-resistive openings patients pedestrian percent permitted persons protected regulations reinforcement resist roof Safety Code sanitary facilities section numbers seismic shear shear wall shower smoke smoke detectors specified in Chapter specified in Section square feet stairway storage space story stress Subsection surface Table tion toilet rooms Type U.B.C. Standard Uniform Building Code ventilation vertical water closet wheelchair width