Page 226-57
... horizontal joints when wall height exceeds length of sheathing panel , and sheathing shall be fastened to the ... Horizontal Force . Wood members shall not be used to resist horizontal forces contributed by masonry or concrete ...
... horizontal joints when wall height exceeds length of sheathing panel , and sheathing shall be fastened to the ... Horizontal Force . Wood members shall not be used to resist horizontal forces contributed by masonry or concrete ...
Page 520-105
... horizontal shear shall be in accordance with Section 2611 ( h ) . 5. Horizontal shear may be investigated by computing the actual compressive or tensile force in any segment , and provisions made to transfer that force as horizontal ...
... horizontal shear shall be in accordance with Section 2611 ( h ) . 5. Horizontal shear may be investigated by computing the actual compressive or tensile force in any segment , and provisions made to transfer that force as horizontal ...
Page
... horizontal . The slope of other ramps shall not be steeper than 1 vertical to 8 horizontal . When provided with fixed seating , the main floor of the assembly room of a Group A , Division 1 , 2 , 2.1 or 3 Occupancy may have a slope not ...
... horizontal . The slope of other ramps shall not be steeper than 1 vertical to 8 horizontal . When provided with fixed seating , the main floor of the assembly room of a Group A , Division 1 , 2 , 2.1 or 3 Occupancy may have a slope not ...
Contents
1 | 30-2 |
Part IIIRequirements Based on Occupancy CHAPTER 5 Classification of All Buildings by Use or Occupancy and General Requirements for All Occu... | 42-4 |
Mixed Occupancy | 42-5 |
Copyright | |
51 other sections not shown
Common terms and phrases
accessible accordance addition apply approved building official building or structure CACAC California ceiling cell Code Sections comply concrete conform corridors Curb ramps dead load detectors devices dimension Division 1 Occupancies doors dwelling units elevator enclosures equipment exceed EXCEPTION existing buildings exit exterior walls fire alarm system fire-resistive construction floor area footcandles grab bar Group H grout handwashing fixture hazard height horizontal inmates installed lateral forces least less live load located masonry materials Matrix Adoption Appendix maximum minimum nonbuilding structures noncombustible nursing occupancy separation occupant load one-hour fire-resistive openings patients pedestrian percent permitted persons protected regulations reinforcement resist roof Safety Code sanitary facilities section numbers seismic shear shear wall shower smoke smoke detectors specified in Chapter specified in Section square feet stairway storage space story stress Subsection surface Table tion toilet rooms Type U.B.C. Standard Uniform Building Code ventilation vertical water closet wheelchair width