Uniform Building Code: State of California ... amendments, Volume 1California Building Standards Commission, 1989 - Building laws |
From inside the book
Results 1-3 of 75
Page 90-59
... located inside all security walls or fences on the property . ( e ) Standpipes shall be located in accordance with Chapter 38 and when located in cell complexes , may be placed in secured pipe chases . Fire Alarm Systems Sec . 1010D ...
... located inside all security walls or fences on the property . ( e ) Standpipes shall be located in accordance with Chapter 38 and when located in cell complexes , may be placed in secured pipe chases . Fire Alarm Systems Sec . 1010D ...
Page 520-47
... located within the spiral shall be not less than 0.01 nor more than 0.08 times net area of concrete section . E. Longitudinal bars located within the spiral may be considered in computing A , and I ,. 8. Tie reinforcement around ...
... located within the spiral shall be not less than 0.01 nor more than 0.08 times net area of concrete section . E. Longitudinal bars located within the spiral may be considered in computing A , and I ,. 8. Tie reinforcement around ...
Page 814-42
... located at the deepest point in the pool . ( c ) Dimensional Tolerance . A construction tolerance shall be permitted ... located on the vertical pool walls at each end and side of the pool at or above the water level . If a pool exceeds ...
... located at the deepest point in the pool . ( c ) Dimensional Tolerance . A construction tolerance shall be permitted ... located on the vertical pool walls at each end and side of the pool at or above the water level . If a pool exceeds ...
Contents
1 | 30-2 |
Part IIIRequirements Based on Occupancy CHAPTER 5 Classification of All Buildings by Use or Occupancy and General Requirements for All Occu... | 42-4 |
Mixed Occupancy | 42-5 |
Copyright | |
51 other sections not shown
Common terms and phrases
accessible accordance addition apply approved building official building or structure CACAC California ceiling cell Code Sections comply concrete conform corridors Curb ramps dead load detectors devices dimension Division 1 Occupancies doors dwelling units elevator enclosures equipment exceed EXCEPTION existing buildings exit exterior walls fire alarm system fire-resistive construction floor area footcandles grab bar Group H grout handwashing fixture hazard height horizontal inmates installed lateral forces least less live load located masonry materials Matrix Adoption Appendix maximum minimum nonbuilding structures noncombustible nursing occupancy separation occupant load one-hour fire-resistive openings patients pedestrian percent permitted persons protected regulations reinforcement resist roof Safety Code sanitary facilities section numbers seismic shear shear wall shower smoke smoke detectors specified in Chapter specified in Section square feet stairway storage space story stress Subsection surface Table tion toilet rooms Type U.B.C. Standard Uniform Building Code ventilation vertical water closet wheelchair width