... allowable unit stresses as hereinafter Members specified . ( b ) Size Determination . Minimum sizes of lumber and ... Allowable Unit Stress on Plans . Where Allowable structures are designed for use of stress grade lumber , struc- Unit ...
... allowable unit stresses as hereinafter Members specified . ( b ) Size Determination . Minimum sizes of lumber and ... Allowable Unit Stress on Plans . Where Allowable structures are designed for use of stress grade lumber , struc- Unit ...
Page 193
... allowable unit stresses as Allowable set forth in Table No. 25 - A for visually graded lumber , and Unit adjustments thereof apply to lumber used under conditions Stresses continuously dry , such as in most covered structures . Under ...
... allowable unit stresses as Allowable set forth in Table No. 25 - A for visually graded lumber , and Unit adjustments thereof apply to lumber used under conditions Stresses continuously dry , such as in most covered structures . Under ...
Page 194
... allowable unit stresses shall be increased in the tables as follows : 15 per cent for two months duration , as for snow 25 per cent for seven days duration 33 per cent for wind or earthquake 100 per cent for impact 3. Allowable plywood ...
... allowable unit stresses shall be increased in the tables as follows : 15 per cent for two months duration , as for snow 25 per cent for seven days duration 33 per cent for wind or earthquake 100 per cent for impact 3. Allowable plywood ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 35 |
Copyright | |
124 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress allowable unit stresses applied approved axial load bars beam bending bolts bond Building Official building or structure ceiling cement cent chimney Code column compression members compressive strength computed conform construction Continued dead load designed diameter distance Douglas Fir exceed exit exterior walls EXTREME FIBER Fire Zone fire-resistive rating flange floor Formula framing gauge girders glued-laminated grade Group grout gypsum height horizontal incombustible joints joists Laminations lath least length less live load longitudinal lumber materials maximum metal minimum Modulus of Elasticity mortar nails occupant load openings parallel to grain permitted perpendicular plaster plate plywood portland cement pounds per square prestressing ratio resist roof Select Structural shear stress shear walls sheathing slab space span specified in Section splices square feet square inch steel studs surface Table thickness tion twelve inches 12 Type U.B.C. Standard values vertical welds width wire wood yield strength