Uniform Building Code, Volume 1International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 82
Page 45
... Fire - Resistive , ” “ Three- Hour Fire - Resistive , " " Two - Hour Fire - Resistive , " and " One- Hour Fire - Resistive . " ( See U.B.C. Standard No. 30-1-67 for fire dampers in air ducts piercing occupancy separations . ) 1. A " Four - ...
... Fire - Resistive , ” “ Three- Hour Fire - Resistive , " " Two - Hour Fire - Resistive , " and " One- Hour Fire - Resistive . " ( See U.B.C. Standard No. 30-1-67 for fire dampers in air ducts piercing occupancy separations . ) 1. A " Four - ...
Page 89
... FIRE ZONES Sec . 1601. ( a ) Fire Zones Defined . For the purpose of General this Code , the entire city is hereby declared to be and is hereby established a Fire District and said Fire District shall be known and designated as Fire ...
... FIRE ZONES Sec . 1601. ( a ) Fire Zones Defined . For the purpose of General this Code , the entire city is hereby declared to be and is hereby established a Fire District and said Fire District shall be known and designated as Fire ...
Page 464
... Fire - resistive Assemblies for Protection of Openings ( d ) Unusable Space Above or Below . In one - hour fire- resistive construction the ceiling may be omitted over unusa- ble space and flooring may be omitted where unusable space ...
... Fire - resistive Assemblies for Protection of Openings ( d ) Unusable Space Above or Below . In one - hour fire- resistive construction the ceiling may be omitted over unusa- ble space and flooring may be omitted where unusable space ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 35 |
Copyright | |
124 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress allowable unit stresses applied approved axial load bars beam bending bolts bond Building Official building or structure ceiling cement cent chimney Code column compression members compressive strength computed conform construction Continued dead load designed diameter distance Douglas Fir exceed exit exterior walls EXTREME FIBER Fire Zone fire-resistive rating flange floor Formula framing gauge girders glued-laminated grade Group grout gypsum height horizontal incombustible joints joists Laminations lath least length less live load longitudinal lumber materials maximum metal minimum Modulus of Elasticity mortar nails occupant load openings parallel to grain permitted perpendicular plaster plate plywood portland cement pounds per square prestressing ratio resist roof Select Structural shear stress shear walls sheathing slab space span specified in Section splices square feet square inch steel studs surface Table thickness tion twelve inches 12 Type U.B.C. Standard values vertical welds width wire wood yield strength