Uniform Building Code, Volume 1International Conference of Building Officials, 1967 - Building laws |
From inside the book
Results 1-3 of 41
Page 8
... Ventilation , and Sanitation 61 706 . Enclosure of Vertical Openings 61 707 . Fire - extinguishing Systems 708 . Special Hazards 709 . Exceptions and Deviations 88555622 60 60 CHAPTER 8 . Requirements for Group C Occupancies SEC . 801 ...
... Ventilation , and Sanitation 61 706 . Enclosure of Vertical Openings 61 707 . Fire - extinguishing Systems 708 . Special Hazards 709 . Exceptions and Deviations 88555622 60 60 CHAPTER 8 . Requirements for Group C Occupancies SEC . 801 ...
Page 69
... Ventilation , ventilation by means of windows or skylights with an area and equal to one - eighth of the total floor area , one - half of which Sanitation shall be openable , or shall be provided with artificial light and a mechanically ...
... Ventilation , ventilation by means of windows or skylights with an area and equal to one - eighth of the total floor area , one - half of which Sanitation shall be openable , or shall be provided with artificial light and a mechanically ...
Page 73
... Ventilation , ventilation by means of windows or skylights with an area and not less than one - eighth of the total floor area , one - half of Sanitation which shall be openable , or shall be provided with artificial light and a ...
... Ventilation , ventilation by means of windows or skylights with an area and not less than one - eighth of the total floor area , one - half of Sanitation which shall be openable , or shall be provided with artificial light and a ...
Contents
HOW TO USE THE UNIFORM BUILDING CODE | 21 |
CHAPTER 3 | 28 |
Part IIDefinitions and Abbreviations | 35 |
Copyright | |
124 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress allowable unit stresses applied approved axial load bars beam bending bolts bond Building Official building or structure ceiling cement cent chimney Code column compression members compressive strength computed conform construction Continued dead load designed diameter distance Douglas Fir exceed exit exterior walls EXTREME FIBER Fire Zone fire-resistive rating flange floor Formula framing gauge girders glued-laminated grade Group grout gypsum height horizontal incombustible joints joists Laminations lath least length less live load longitudinal lumber materials maximum metal minimum Modulus of Elasticity mortar nails occupant load openings parallel to grain permitted perpendicular plaster plate plywood portland cement pounds per square prestressing ratio resist roof Select Structural shear stress shear walls sheathing slab space span specified in Section splices square feet square inch steel studs surface Table thickness tion twelve inches 12 Type U.B.C. Standard values vertical welds width wire wood yield strength